Bs9999 2008 recommends for fire doors with cold smoke control that the threshold gap should be either less than 3mm in height or should be fitted with a threshold seal.
Fire door gaps uk.
This makes the gap between the carpet and doors around 10 15mm.
Nfpa 80 fire doors and other opening protectives.
In general clearance for those allowed gaps are as follows.
Contains information on maximum gap allowances for different types of fire doors.
It s recommended to aim for a 3mm gap to ensure adequate room for the intumescent strips to activate in the event of a fire and for the smoke seal strips if installed to not get damaged by the opening and closing of the door.
If there isn t one it is most likely not a fire door and will not protect you in a fire.
How much can you cut off a fire door.
Nothing must be cut at the top at all and the certification label must remain intact.
Please could you confirm or otherwise my understanding that the maximim 8 10mm gap usually cited as permissible at the bottom of the fire door should be to allow for the carpet i e.
Regulations which apply the directive and its requirements in the uk.
I work in a relatively new office buiding that has internal fire doors with cold smoke seals and the gaps under the doors range from 5mm to 10mm.
It should be 8 10mm max from bottom of the door to the surface onto which the carpet etc is laid.
Check for a label or a plug on top or on the side of each door for a fire resistance rating.
Underneath the fire door a gap of 8mm is traditionally acceptable although for fire doors that are required to limit spread of cold smoke only 3 mm is permissible with a threshold seal to be fitted if the gap is bigger.
Ce marked hinges tested to bs en1935 should be used on fire or smoke.
Under the bottom of a door.
Fire doors basic guidance.
All fire doors display certificates and relevant markings to verify their fire integrity.
In general the gap should not exceed 3mm along the 2 long edges and across top of the door leaf to facilitate checking of the gap on site a bwf fire door alliance scheme gap.
1 8 for more detailed gap information refer to nfpa 80 section 6 3 1 7 and section.
The gap between the door and the frame is extremely important and must be suitable for the intumescent seal fitted.
What gaps are required around a door and its frame.
1 8 meeting edges for a pair of doors.
Gaps between fire doors and the door frame should never be more than 4mm or less than 2mm.
3 4 between door and frame.